setreast.blogg.se

Candela unit
Candela unit











Its mission is to promote innovation and industrial competitiveness. The National Institute of Standards and Technology is a physical sciences laboratory and a non-regulatory agency of the United States Department of Commerce. 1 Candela/square meter 1 Lambert Divide the number by 1 to convert Candela/square meter to Lambert. SI Unit for luminous intensity is candela and scale factor of this measurement unit is 1.There are total 22 unit conversions for luminous intensity measurement. In 1979, because of the experimental difficulties in realizing a Planck radiator at high temperatures and the new possibilities offered by radiometry, i.e., the measurement of optical radiation power, the 16th CGPM (1979) adopted a new definition of the candela: the candela is the luminous intensity, in a given direction, of a source that emits monochromatic radiation of frequency 540 x 1012 hertz and that has a radiant intensity in that direction of 1/683 watt per steradian. Candela is a measurement unit for luminous intensity.Its Symbol is cd and alternate name for this unit is Not Available.It is the default SI Unit of luminous intensity category. It was then ratified in 1948 by the 9th CGPM which adopted a new international name for this unit, the candela (symbol cd) in 1967 the 13th CGPM gave an amended version of the 1946 definition. This modification had been prepared by the International Commission on Illumination (CIE) and by the CIPM before 1937, and was promulgated by the CIPM in 1946. The units of luminous intensity based on flame or incandescent filament standards in use in various countries before 1948 were replaced initially by the 'new candle' based on the luminance of a Planckian radiator (a blackbody) at the temperature of freezing platinum.

candela unit

But a standard based on incandescent lamps, and consequently dependent upon their stability, would never have been fully satisfactory and could therefore be only provisional on the other hand, the properties of a blackbody provided a theoretically perfect solution and, as early as 1933, the principle was adopted that new photometric units would be based on the luminous emission of a blackbody at the freezing temperature of platinum (2045 K). Germany, at the same time, stayed with the Hefner candle, defined by a flame standard, and equal to about nine-tenths of an international candle.

candela unit

Originally, each country had its own, and rather poorly reproducible, unit of luminous intensity it was necessary to wait until 1909 to see a beginning of unification on the international level, when the national laboratories of the United States of America, France, and Great Britain decided to adopt the international candle represented by carbon filament lamps.













Candela unit